  1. Attribute VB_Name = "Module1"
  2. Public NOD, Dev As Long
  3. Public serial, version As String
  4.  
  5.  
  6. Type USMCMode
  7.     PMode As Long       'Turn off buttons (TRUE - buttons disabled)
  8.     PReg As Long        'Current reduction regime (TRUE - regime is on)
  9.     ResetD As Long      'Turn power off and make a whole step (TRUE - apply)
  10.     EmReset As Long     'Quick power off
  11.     Tr1T As Long        'Trailer 1 TRUE state (TRUE : +3/+5Â; FALSE : 0Â)
  12.     Tr2T As Long        'Trailer 2 TRUE state (TRUE : +3/+5Â; FALSE : 0Â)
  13.     RotTrT As Long      'Rotary Transducer TRUE state (TRUE : +3/+5Â; FALSE : 0Â)
  14.     TrSwap As Long      'If TRUE, Trailers are treated to be swapped
  15.     Tr1En As Long       'If TRUE Trailer 1 Operation Enabled
  16.     Tr2En As Long       'If TRUE Trailer 2 Operation Enabled
  17.     RotTeEn As Long     'If TRUE Rotary Transducer Operation Enabled
  18.     RotTrOp As Long     'Rotary Transducer Operation Select (stop on error for TRUE)
  19.     Butt1T As Long      'Button 1 TRUE state (TRUE : +3/+5Â; FALSE : 0Â)
  20.     Butt2T As Long      'Button 2 TRUE state (TRUE : +3/+5Â; FALSE : 0Â)
  21.     ResetRT As Long     'Reset Rotary Transducer Check Positions (need one full revolution before it can detect error)
  22.     SyncOUTEn As Long   'If TRUE output syncronization enabled
  23.     SyncOUTR As Long    'If TRUE output synchronization counter will be reset
  24.     SyncINOp As Long    'Synchronization input mode:
  25.                         'True - Step motor will move one time to the destination position
  26.                         'False - Step motor will move multiple times by steps equal to the value destination position
  27.     SyncCount As Long   'Number of steps after which synchronization output sygnal occures
  28.     SyncInvert As Long  'Set to TRUE to invert output synchronization signal
  29. End Type
  30.  
  31. Type USMCParameters
  32.     AccelT As Single        'Acceleration time (in ms)
  33.     DecelT As Single        'Deceleration time (in ms)
  34.     PTimeout As Single      'Time (in ms) after which current will be reduced to 60% of normal
  35.     BTimeout1 As Single     'Time (in ms) after which speed of step motor rotation will be equal to the one specified at
  36.                             'BTO1P field (see below). (This parameter is used when controlling step motor using buttons)
  37.     BTimeout2 As Single     '
  38.     BTimeout3 As Single     '
  39.     BTimeout4 As Single     '
  40.     BTimeoutR As Single     'Time (in ms) after which reset command will be performed
  41.     BTimeoutD As Single     'This field is reserved for future use
  42.     MinP As Single          'Speed (steps/sec) while performing reset operation. (This parameter is used when controlling
  43.                             'step motor using buttons)
  44.     BTO1P As Single         'Speed (steps/sec) after BTIMEOUT 1 time have passed. (This parameter is used when controlling
  45.                             'step motor using buttons)
  46.     BTO2P As Single         '
  47.     BTO3P As Single         '
  48.     BTO4P As Single         '
  49.     MaxLoft As Long         'Value in full steps that will be used performing backlash operation
  50.     StartPos As Long        'This field is reserved for future use
  51.     RTDelta As Integer      'Revolution distance – number of full steps per one full revolution
  52.     RTMinErr As Integer     'Number of full steps missed to raise the error flag
  53.     MaxTemp As Single       'Maximum allowed temperature (Celsius)
  54.     SynOUTP As Long         'Duration of the output synchronization pulse
  55.     LoftPeriod As Single    'Speed of the last phase of the backlash operation.
  56. End Type
  57.  
  58. Type USMCStartParameters
  59.     SDivisor As Long    'Step is divided by this factor (1,2,4,8)
  60.     DefDir As Long      'Direction for backlash operation (relative)
  61.     LoftEn As Long      'Enable automatic backlash operation (works if slow start/stop mode is off)
  62.     SlStart As Long     'If TRUE slow start/stop mode enabled.
  63.     WSyncIN As Long     'If TRUE controller will wait for input synchronization signal to start
  64.     SyncOUTR As Long    'If TRUE output synchronization counter will be reset
  65.     ForceLoft As Long   'If TRUE and destination position is equal to the current position backlash operation will be performed.
  66. End Type
  67.  
  68. Type USMCState
  69.     CurPos As Long      'Current position (in microsteps)
  70.     Temp As Single      'Current temperature of the driver
  71.     SDivisor As Long    'Step is divided by this factor
  72.     Loft As Long        'Indicates backlash status
  73.     FullPower As Long   'If TRUE then full power.
  74.     CW_CCW As Long      'Current direction. Relatively!
  75.     Power As Long       'If TRUE then Step Motor is ON.
  76.     FullSpeed As Long   'If TRUE then full speed. Valid in "Slow Start" mode only.
  77.     AReset As Long      'TRUE After Device reset, FALSE after "Set Position".
  78.     RUN As Long         'Indicates if step motor is rotating
  79.     SyncIN As Long      'Logical state directly from input synchronization PIN
  80.     SyncOUT As Long     'Logical state directly from output synchronization PIN
  81.     RotTr As Long       'Indicates current rotary transducer press state
  82.     RotTrErr As Long    'Indicates rotary transducer error flag
  83.     EmReset As Long     'Indicates state of emergency disable button (local control)
  84.     Trailer1 As Long    'Indicates trailer 1 logical state.
  85.     Trailer2 As Long    'Indicates trailer 2 logical state.
  86.     Voltage As Single   'Input power source voltage (6-39V) -=24 version 0nly=-
  87. End Type
  88.  
  89. Declare Sub USMCGetLastErr Lib "USMCVBDLL.dll" _
  90.     Alias "_USMCVB_GetLastErr@8" (ByVal ErrStr As String, ByVal vlen As Long)
  91.  
  92. Declare Function USMCInit Lib "USMCVBDLL.dll" _
  93.     Alias "_USMCVB_Init@20" (ByRef value As Long, ByVal versions As String, _
  94.     ByVal vlen As Long, ByVal serials As String, ByVal slen As Long) As Long
  95.  
  96. Declare Function USMCGetState Lib "USMCVBDLL.dll" _
  97.     Alias "_USMCVB_GetState@8" (ByVal Dev As Long, ByRef Str As USMCState) As Long
  98.  
  99. Declare Function USMCGetStartParameters Lib "USMCVBDLL.dll" _
  100.     Alias "_USMCVB_GetStartParameters@8" (ByVal Dev As Long, ByRef Str As USMCStartParameters) As Long
  101. Declare Function USMCStart Lib "USMCVBDLL.dll" _
  102.     Alias "_USMCVB_Start@16" (ByVal Dev As Long, ByVal DestPos As Long, ByRef Speed As Single, _
  103.                               ByRef Str As USMCStartParameters) As Long
  104.  
  105. Declare Function USMCStop Lib "USMCVBDLL.dll" _
  106.     Alias "_USMCVB_Stop@4" (ByVal Dev As Long) As Long
  107.  
  108. Declare Function USMCGetMode Lib "USMCVBDLL.dll" _
  109.     Alias "_USMCVB_GetMode@8" (ByVal Dev As Long, ByRef Str As USMCMode) As Long
  110. Declare Function USMCSetMode Lib "USMCVBDLL.dll" _
  111.     Alias "_USMCVB_SetMode@8" (ByVal Dev As Long, ByRef Str As USMCMode) As Long
  112.  
  113. Declare Function USMCGetParameters Lib "USMCVBDLL.dll" _
  114.     Alias "_USMCVB_GetParameters@8" (ByVal Dev As Long, ByRef Str As USMCParameters) As Long
  115. Declare Function USMCSetParameters Lib "USMCVBDLL.dll" _
  116.     Alias "_USMCVB_SetParameters@8" (ByVal Dev As Long, ByRef Str As USMCParameters) As Long
  117.  
  118. Declare Function USMCSaveParametersToFlash Lib "USMCVBDLL.dll" _
  119.     Alias "_USMCVB_SaveParametersToFlash@4" (ByVal Dev As Long) As Long
  120.  
  121. Declare Function USMCSetCurrentPosition Lib "USMCVBDLL.dll" _
  122.     Alias "_USMCVB_SetCurrentPosition@8" (ByVal Dev As Long, ByRef Str As USMCParameters) As Long
  123.  
  124.  
  125. Sub PrintDMode(mode As USMCMode)
  126.     Dim out As String
  127.     out = "Mode parameters:" & (Chr(13))
  128.     out = out & "Buttons - "
  129.     If mode.PMode <> 0 Then
  130.         out = out & "Disabled" & (Chr(13))
  131.     Else
  132.         out = out & "Enabled" & (Chr(13)) & "Button 1 TRUE state - "
  133.         If mode.Butt1T <> 0 Then
  134.             out = out & "+3/+5 V" & (Chr(13))
  135.         Else
  136.             out = out & "0 V(GND)" & (Chr(13))
  137.         End If
  138.         out = out & "Button 2 TRUE state - "
  139.         If mode.Butt2T <> 0 Then
  140.             out = out & "+3/+5 V" & (Chr(13))
  141.         Else
  142.             out = out & "0 V(GND)" & (Chr(13))
  143.         End If
  144.     End If
  145.     out = out & "Current reduction regime - "
  146.     If mode.PReg <> 0 Then
  147.         out = out & "Used" & (Chr(13))
  148.     Else
  149.         out = out & "Not Used" & (Chr(13))
  150.     End If
  151.    
  152.     If mode.ResetD <> 0 Then
  153.         out = out & "Power - "
  154.         If mode.EmReset <> 0 Then
  155.             out = out & "Emerjency Off" & (Chr(13))
  156.         Else
  157.             out = out & "Off" & (Chr(13))
  158.         End If
  159.     Else
  160.         out = out & "Power - On" & (Chr(13))
  161.     End If
  162.     If mode.Tr1En <> 0 Or mode.Tr2En <> 0 Then
  163.         out = out & "Trailers are - "
  164.         If mode.TrSwap <> 0 Then
  165.             out = out & "Swapped" & (Chr(13))
  166.         Else
  167.             out = out & "Direct" & (Chr(13))
  168.         End If
  169.     End If
  170.     out = out & "Trailer 1 - "
  171.     If mode.Tr1En <> 0 Then
  172.         out = out & "Enabled" & (Chr(13)) & "Trailer 1 TRUE state - "
  173.         If mode.Tr1T <> 0 Then
  174.             out = out & "+3/+5 V" & (Chr(13))
  175.         Else
  176.             out = out & "0 V(GND)" & (Chr(13))
  177.         End If
  178.     Else
  179.         out = out & "Disabled" & (Chr(13))
  180.     End If
  181.     out = out & "Trailer 2 - "
  182.     If mode.Tr2En <> 0 Then
  183.         out = out & "Enabled" & (Chr(13)) & "Trailer 2 TRUE state - "
  184.         If mode.Tr2T <> 0 Then
  185.             out = out & "+3/+5 V" & (Chr(13))
  186.         Else
  187.             out = out & "0 V(GND)" & (Chr(13))
  188.         End If
  189.     Else
  190.         out = out & "Disabled" & (Chr(13))
  191.     End If
  192.     out = out & "Rotary Transducer - "
  193.     If mode.RotTeEn <> 0 Then
  194.         out = out & "Enabled" & (Chr(13)) & "Rotary Transducer TRUE state - "
  195.         If mode.RotTrT <> 0 Then
  196.             out = out & "+3/+5 V" & (Chr(13))
  197.         Else
  198.             out = out & "0 V(GND)" & (Chr(13))
  199.         End If
  200.         out = out & "Rotary Transducer Operation - "
  201.         If mode.RotTrOp <> 0 Then
  202.             out = out & "Stop on error" & (Chr(13))
  203.         Else
  204.             out = out & "Check and ignore error" & (Chr(13))
  205.         End If
  206.         out = out & "Reset Rotary Transducer Check Positions - "
  207.         If mode.ResetRT <> 0 Then
  208.             out = out & "Initiated" & (Chr(13))
  209.         Else
  210.             out = out & "No, why?" & (Chr(13))
  211.         End If
  212.     Else
  213.         out = out & "Disabled" & (Chr(13))
  214.     End If
  215.     out = out & "Output Syncronization - "
  216.     If mode.SyncOUTEn <> 0 Then
  217.         out = out & "Enabled" & (Chr(13)) & "Reset Output Synchronization Counter - "
  218.         If mode.SyncOUTR <> 0 Then
  219.             out = out & "Initiated" & (Chr(13))
  220.         Else
  221.             out = out & "No, why?" & (Chr(13))
  222.         End If
  223.         out = out & "Number of steps after which synchronization output sygnal occures - " & mode.SyncCount & (Chr(13))
  224.     Else
  225.         out = out & "Disabled" & (Chr(13))
  226.     End If
  227.     out = out & "Synchronization input mode:" & (Chr(13))
  228.     If mode.SyncINOp <> 0 Then
  229.         out = out & "Step motor will move one time to the destination position" & (Chr(13))
  230.     Else
  231.         out = out & "Step motor will move multiple times by [destination position]" & (Chr(13))
  232.     End If
  233.     out = out & "Synchronization Output - "
  234.     If mode.SyncInvert <> 0 Then
  235.         out = out & "INVERTED" & (Chr(13))
  236.     Else
  237.         out = out & "NORMAL" & (Chr(13))
  238.     End If
  239.     MsgBox out, vbOKOnly, "USMC_SetMode Successful"
  240. End Sub
  241.  
  242. Sub PrintDState(state As USMCState)
  243. Dim out As String
  244. With state
  245.     out = "The state is:" & (Chr(13))
  246.     out = out & "- Current Position in microsteps - " & Format(.CurPos) & (Chr(13))
  247.     out = out & "- Temperature - " & Format(.Temp, "0.00") & (Chr(176)) & (Chr(67)) & (Chr(13))
  248.     out = out & "- Step Divisor - " & Format(.SDivisor, "0") & (Chr(13))
  249.     out = out & "- Loft State - "
  250.     If .Loft <> 0 Then
  251.         out = out & "Indefinite" & (Chr(13))
  252.     Else
  253.         out = out & "Fixed" & (Chr(13))
  254.     End If
  255.     out = out & "- Power - "
  256.     If .Power <> 0 Then
  257.         If .FullPower <> 0 Then
  258.             out = out & "Full" & (Chr(13))
  259.         Else
  260.             out = out & "Half" & (Chr(13))
  261.         End If
  262.     Else
  263.         out = out & "Off" & (Chr(13))
  264.     End If
  265.     If .RUN <> 0 Then
  266.         out = out & "- Step Motor is Running in "
  267.         If .CW_CCW <> 0 Then
  268.             out = out & "CCW Direction "
  269.         Else
  270.             out = out & "CW Direction "
  271.         End If
  272.         If (.SDivisor = 1) And (.FullSpeed <> 0) Then
  273.             out = out & "at Full Speed" & (Chr(13))
  274.         Else
  275.             out = out & (Chr(13))
  276.         End If
  277.     Else
  278.         out = out & "- Step Motor is Not Running" & (Chr(13))
  279.     End If
  280.     out = out & "- Device "
  281.     If .AReset <> 0 Then
  282.         out = out & "is After Reset" & (Chr(13))
  283.     Else
  284.         out = out & "Position Already Set" & (Chr(13))
  285.     End If
  286.     out = out & "- Input Synchronization Logical Pin State - "
  287.     If .SyncIN <> 0 Then
  288.         out = out & "TRUE" & (Chr(13))
  289.     Else
  290.         out = out & "FALSE" & (Chr(13))
  291.     End If
  292.     out = out & "- Output Synchronization Logical Pin State - "
  293.     If .SyncOUT <> 0 Then
  294.         out = out & "TRUE" & (Chr(13))
  295.     Else
  296.         out = out & "FALSE" & (Chr(13))
  297.     End If
  298.     out = out & "- Rotary Transducer Logical Pin State - "
  299.     If .RotTr <> 0 Then
  300.         out = out & "TRUE" & (Chr(13))
  301.     Else
  302.         out = out & "FALSE" & (Chr(13))
  303.     End If
  304.     out = out & "- Rotary Transducer Error Flag - "
  305.     If .RotTrErr <> 0 Then
  306.         out = out & "Error" & (Chr(13))
  307.     Else
  308.         out = out & "Clear" & (Chr(13))
  309.     End If
  310.     out = out & "- Emergency Disable Button - "
  311.     If .EmReset <> 0 Then
  312.         out = out & "Pushed" & (Chr(13))
  313.     Else
  314.         out = out & "Unpushed" & (Chr(13))
  315.     End If
  316.     out = out & "- Trailer 1 Press State - "
  317.     If .Trailer1 <> 0 Then
  318.         out = out & "Pushed" & (Chr(13))
  319.     Else
  320.         out = out & "Unpushed" & (Chr(13))
  321.     End If
  322.     out = out & "- Trailer 2 Press State - "
  323.     If .Trailer2 <> 0 Then
  324.         out = out & "Pushed" & (Chr(13))
  325.     Else
  326.         out = out & "Unpushed" & (Chr(13))
  327.     End If
  328.     out = out & "- Input Voltage - "
  329.     If .Voltage = 0 Then
  330.         out = out & "Low" & (Chr(13))
  331.     Else
  332.         out = out & Format(.Voltage, "0.0") & (Chr(13))
  333.     End If
  334.     MsgBox out, vbOKOnly, "USMC_GetState Successful"
  335. End With
  336. End Sub
  337.  
  338. Sub PrintError()
  339.     Dim out As String
  340.     out = String(1000, 0)
  341.     USMCGetLastErr out, 1000
  342.     MsgBox out, vbOKOnly, "Error"
  343. End Sub
  344.  
  345. Sub PrintDStartParameters(DPos As Long, Speed As Single, sp As USMCStartParameters)
  346. With sp
  347.     Dim out As String
  348.     out = "Destination position - " & Format(DPos) & (Chr(13))
  349.     out = out & "Speed - " & Format(Speed, "##.00") & " tacts/s" & (Chr(13))
  350.     out = out & "Steps Divisor - " & Format(.SDivisor, "0") & (Chr(13))
  351.     If .SDivisor = 1 Then
  352.         out = out & "Slow start/stop mode - "
  353.         If .SlStart <> 0 Then
  354.             out = out & "Enabled" & (Chr(13))
  355.         Else
  356.             out = out & "Disabled" & (Chr(13))
  357.         End If
  358.     Else
  359.         out = out & "Automatic backlash operation - "
  360.         If .LoftEn <> 0 Then
  361.             out = out & "Enabled" & (Chr(13))
  362.             out = out & "Automatic backlash operation direction - "
  363.             If .DefDir <> 0 Then
  364.                 out = out & "CCW" & (Chr(13))
  365.             Else
  366.                 out = out & "CW" & (Chr(13))
  367.             End If
  368.             out = out & "Force automatic backlash operation - "
  369.             If .ForceLoft <> 0 Then
  370.                 out = out & "TRUE" & (Chr(13))
  371.             Else
  372.                 out = out & "FALSE" & (Chr(13))
  373.             End If
  374.         Else
  375.             out = out & "Disabled" & (Chr(13))
  376.         End If
  377.     End If
  378.     If .WSyncIN <> 0 Then
  379.         out = out & "Controller will wait for input synchronization signal to start" & (Chr(13))
  380.     Else
  381.         out = out & "Input synchronization signal ignored" & (Chr(13))
  382.     End If
  383.     If .SyncOUTR <> 0 Then
  384.         out = out & "Output synchronization counter will be reset" & (Chr(13))
  385.     Else
  386.         out = out & "Output synchronization counter will not be reset" & (Chr(13))
  387.     End If
  388.    
  389.     MsgBox out, vbOKOnly, "USMC_Start Successful"
  390.  
  391. End With
  392. End Sub
  393.  
  394. Sub PrintDParameters(Parameters As USMCParameters)
  395. With Parameters
  396.     Dim out As String
  397.     out = "The parameters are:" & (Chr(13))
  398.     out = out & "Full acceleration time - " & Format(.AccelT, "###0") & " ms" & (Chr(13))
  399.     out = out & "Full deceleration time - " & Format(.DecelT, "###0") & " ms" & (Chr(13))
  400.     out = out & "Power reduction timeout - " & Format(.PTimeout, "###0") & " ms" & (Chr(13))
  401.     out = out & "Button speedup timeout 1 - " & Format(.BTimeout1, "###0") & " ms" & (Chr(13))
  402.     out = out & "Button speed after timeout 1 - " & Format(.BTO1P, "###0.00") & " steps/s" & (Chr(13))
  403.     out = out & "Button speedup timeout 2 - " & Format(.BTimeout2, "###0") & " ms" & (Chr(13))
  404.     out = out & "Button speed after timeout 2 - " & Format(.BTO2P, "###0.00") & " steps/s" & (Chr(13))
  405.     out = out & "Button speedup timeout 3 - " & Format(.BTimeout3, "###0") & " ms" & (Chr(13))
  406.     out = out & "Button speed after timeout 3 - " & Format(.BTO3P, "###0.00") & " steps/s" & (Chr(13))
  407.     out = out & "Button speedup timeout 4 - " & Format(.BTimeout4, "###0") & " ms" & (Chr(13))
  408.     out = out & "Button speed after timeout 4 - " & Format(.BTO4P, "###0.00") & " steps/s" & (Chr(13))
  409.     out = out & "Button reset timeout - " & Format(.BTimeoutR, "###0") & " ms" & (Chr(13))
  410.     out = out & "Button reset operation speed - " & Format(.MinP, "###0.00") & " steps/s" & (Chr(13))
  411.     out = out & "Backlash operation distance - " & Format(.MaxLoft) & " steps" & (Chr(13))
  412.     out = out & "Revolution distance - " & Format(.RTDelta) & " steps" & (Chr(13))
  413.     out = out & "Minimal revolution distance error - " & Format(.RTMinErr) & " steps" & (Chr(13))
  414.     out = out & "Power off temperature - " & Format(.MaxTemp, "##0.00") & (Chr(176)) & (Chr(67)) & (Chr(13))
  415.     out = out & "Duration of the output synchronization pulse - "
  416.     If .SynOUTP = 0 Then
  417.        out = out & "minimal" & (Chr(13))
  418.     Else
  419.        out = out & Format(.SynOUTP - 0.5, "##0.0") & " * [Tact Period]" & (Chr(13))
  420.     End If
  421.     out = out & "Speed of the last phase of the backlash operation - "
  422.     If .LoftPeriod = 0 Then
  423.        out = out & "normal" & (Chr(13))
  424.     Else
  425.        out = out & Format(.LoftPeriod - 0.5, "###0.00") & " steps/s" & (Chr(13))
  426.     End If
  427.     MsgBox out, vbOKOnly, "USMC_SetParameters Successful"
  428.  