Blame | Last modification | View Log | RSS feed
---6.12.2006uSMC2504Controller response to EMStop signal is changed:EMStop indicator in controller program andpower off action by controller program happen with1 second delay now.---28.09.2006uSMC2503Bug that result in wrong identification of “Destination position”field of StartParameters structure in sequence:USMC_GetMode(Dev, Mode) ;USMC_GetStartParameters(Dev, StartParameters) ;StartParameters.SDivisor = 1; // Full step modeUSMC_Start(Dev, DestPos, Speed, StartParameters);// Wait when motor stopMode.ResetD = TRUE; // Turn power offUSMC_SetMode(Dev, Mode);Mode.ResetD = FALSE; // Turn power onUSMC_SetMode(Dev, Mode);StartParameters.SDivisor = 8; // Microstep modeUSMC_Start(Dev, DestPos, Speed, StartParameters);is corrected.---03.07.2006uSMC2502Possibility of quadrature encoder using is added.---02.06.2006uSMC2407Possibility of control of stepper motor windings energizing aftercontroller switching on is added. Now, when controller is switching onthe stepper motor windings energizing status is just the same as itwas saved in controller flash-memory when USMC_SaveParametersToFlash()function was called last time.