Subversion Repositories f9daq

Compare Revisions

Ignore whitespace Rev 127 → Rev 128

/lab/sipmscan/trunk/README
37,6 → 37,7
- scope IP -> sets the oscilloscope IP address
- LASER settings info panel -> this will be written to the output file and is used for supplying additional information
- chamber temperature -> the chamber temperature to be written to the output file
- incidence angle -> the angle at which the sample is rotated around its axis, relative to the LASER beam (0 degrees is perpendicular to LASER beam)
 
b) Main measurement window:
- settings for table position and bias voltage
53,6 → 54,7
- if using multiple files, use multiple file select or select all listed files
- files will be used in order displayed on the list
- to clear the complete list, use the clear list button
- any opened measurement has an info display of its header at the bottom for easier navigation
 
d) Histogram window:
- displays the currently selected histogram in the histogram file selection window
76,12 → 78,16
- Fit spectrum -> fit the currently open spectrum for peaks
- Fit all selected -> fit all the selected ADC spectra selected in the histogram file selection window for peaks and display the breakdown voltage plots
- Integrate spectrum (X, Y) -> integrate the ADC spectrum for multiple files with an X or Y scan (used for edge scans)
- Relative PDE -> calculation of the relative PDE for the currently selected files
 
c) Windows:
- Specific tiling
c) Tools:
- Fieldpoint temperature sensor -> direct graphing of the fieldpoint temperature sensor (with settings for fieldpoint channel, start time and end time), output is a graph (if exporting) and a comma separated list saved to folder ./fieldpoint
 
d) Windows:
- Specific window tiling
- Switch between active windows
 
d) Help information
e) Help information
 
Important!
When using any analysis method (surface 2D plot, fitting, integration, ADC spectra display) only events inside the selected TDC window will be used so set the TDC range accordingly.
89,12 → 95,18
______________
4. Change log:
 
9.4.2015:
5.5.2015 (Current Rev):
a) Added a header display for opened files in the histogram file selection window. This enables a quicker view of the measurement information.
b) Added an incidence angle input to be able to save sample rotation angle to headers of files.
c) Added support for the fieldpoint temperature sensor (FP RTD 122). Can now plot and export data from the sensor for a specific channel and specific time range. For now, this option only works if the PC you are using this program on is connected to an internet/ethernet connection at IJS.
d) Added a limited relative PDE analysis option. At this time, it takes the selected files and calculates the PDE, relative to the first selected file. The first file should be measured at incidence angle 0, with others having an incidence angle shift of +15 (1st file -> 0, 2nd file -> 15, 3rd file -> 30,...).
 
9.4.2015 (Rev 127):
a) Added communications panel for connecting to a Tektronix scope.
b) Added limited support for waveform analysis with a Tektronix scope. For now it only works when linking it to CAMAC acquisition.
b) Added limited support for waveform analysis with a Tektronix scope. For now, it only works when linking it to CAMAC acquisition.
c) Added a manual chamber temperature entry field.
 
16.3.2015:
16.3.2015 (Rev 117):
a) First version of sipmscan.
b) Added support for CAMAC, bias voltage settings and table position settings.
c) Added support for opening measured histograms.